6
2 For your safety
VEGAPULS 64 • Two-wire 4 … 20 mA/HART
51141-EN-210219
2.5 EU conformity
ThedevicefullsthelegalrequirementsoftheapplicableEUdirec-
tives.ByaxingtheCEmarking,weconrmtheconformityofthe
instrument with these directives.
The EU conformity declaration can be found on our homepage.
2.6 NAMUR recommendations
NAMUR is the automation technology user association in the process
industry in Germany. The published NAMUR recommendations are
acceptedasthestandardineldinstrumentation.
ThedevicefullstherequirementsofthefollowingNAMURrecom-
mendations:
NE 21 – Electromagnetic compatibility of equipment
NE 43 – Signal level for fault information from measuring transduc-
ers
NE53–Compatibilityofelddevicesanddisplay/adjustment
components
NE107–Self-monitoringanddiagnosisofelddevices
For further information see www.namur.de.
2.7 Radio license for Europe
The instrument was tested according to the latest issue of the follow-
ingharmonizedstandards:
EN 302372 - Tank Level Probing Radar
EN 302729 - Level Probing Radar
It is hence approved for use inside and outside closed vessels in
countries of the EU.
Use is also approved in EFTA countries, provided the respective
standards have been implemented.
For operation inside of closed vessels, points a to f in annex E of
EN302372mustbefullled.
For operation outside of closed vessels, the following conditions must
befullled:
The instrument must be stationary mounted and the antenna
directed vertically downward
The instrument may only be used outside closed vessels in the
version with G1½ or 1½ NPT thread with integrated horn antenna.
The mounting location must be at least 4 km away from radio
astronomy stations, unless special permission was granted by the
responsible national approval authority
When installed within 4 to 40 km of a radio astronomy station,
the instrument must not be mounted higher than 15 m above the
ground.
A list of the respective radio astronomy stations can be found in chap-
ter " Appendix" of the operating instructions.