DISPLAY CAUSE SOLUTION
MAINTENANCE ALARM
This alarm signals the need to
carry our the machine mainte-
nance.
Menu > Maintenance > change
date or cycle number and press
the key
to reset the inner
counter.
BATTERY ALARM
This alarm signals the need to
change the button cell (model
CR2032) of the dosage control
unit. This button cell is needed to
store meter and date / time infor-
mation.
Replace the button cell (model
CR2032).
EEPROM WRITE
ALARM
This error signals a failure of
the control unit EEPROM. The
EEPROM is written when control
unit information are saved: meter
updating after a dosage/delivery
,
setting saving, dose and error pro-
gramming.
t $IFDL XIFUIFS UIF FSSPS TUJMM
occurs by performing program-
ming tests.
t 3FQMBDFUIFDBSE
RTC READ ALARM
This error signals a reading error
of the control unit RTC (real-time
clock). The R
TC is read during the
loading of a meter or the date/hour.
t $IFDL XIFUIFS UIF FSSPS TUJMM
occurs by performing program-
ming tests.
t 3FQMBDFUIFDBSE
RTC WRITE ERROR
This error signals a writing error of
the control unit RTC. The RTC is
written during the saving of a meter
(after a delivery/dosage) or of the
date/hour
.
t $IFDL XIFUIFS UIF FSSPS TUJMM
occurs by performing program-
ming tests.
t 3FQMBDFUIFDBSE
GROUP DOSE ERROR
This error signals that no pulses
were received within 3 seconds
from the dosage beginning of that
unit and it can be due to a failur
e
of the flowmeter or the control unit
pulses.
Check the flowmeter and the con-
nections to the control unit.
GROUP POUR ERROR
This error signals that the unit
delivery exceeded the limit time
of 240 secs. and this can be due
to a failure of the flowmeter or the
inputs of control unit pulses.
Check the flowmeter and the con-
nections to the control unit.
PRESSURE ERROR
This err
or signals the pressure
detected by the heater pressure
switch is above the value of 1.60
Bar.
Check the pr
essure switch and, if
necessary, inspect the heating ele-
ment or its manual reset.
The alarms and the errors signalled by the TFT-series control units are listed below. Please note that
some alarm or error messages are significant only from certain releases on.
SERVICE MANUAL
9.2
Edition 01 of 08/2017

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Victoria Arduino BLACK EAGLE VA388 and is the answer not in the manual?

Victoria Arduino BLACK EAGLE VA388 Specifications

General IconGeneral
BrandVictoria Arduino
ModelBLACK EAGLE VA388
CategoryCoffee Maker
LanguageEnglish

Related product manuals