12.11 BOILER ERROR
Unit X is hot, but the coffee is
dispensed completely cold.
Problem with the coffee boiler
Menu->Set point
Temperature-> Boiler
temperatures. Read
the second line:
Boiler temperatures
All boilers except
for X are okay?
Check that relay
connector cable is
integral
Substitute the cable
Check that the LED
of boiler X of the
relay is always alight
Check the continuity
of the thermal fuse
of the boiler
Substitute the
thermal fuse
If the value is 0V when
the LED is on:
substitute the boiler
If the value is 230V
when the LED is on:
substitute the relay
unit
What is
the voltage of boiler
X’s relay?
NO
SI
SI
SI
NO
NO
NO