WARNING
Every time you work directly with the heater it
is important to ensure that the internal pres-
sure is zero. Completely remove the water
inside for operations that require it.
To empty the heater proceed as follows:
1 Turn off the machine and let out all the steam
by opening the steam pipes completely to
quickly decrease internal pressure.
2 Remove the work surface and loosen the
screws to remove the side panel as shown
in chapter 3.
5.1 EMPTYING THE HEATER
DANGER
Before proceeding with the operations
described in the chapter make sure that the
machine is turned off and unplugged from the
mains. Discharge any residual pressure pre-
sent in the steam circuit.
WARNING
Before emptying the boiler, disconnect the
water inlets inside the water circuit by turning
off the inlet tap and disconnecting the tube.
These operations are necessary to avoid any
water leakage inside the machine that may
cause damage.
DANGER
Fig. 110
Edition 01 of 08/2017
5.2
SERVICE MANUAL
Fig. 112
Fig. 111