t CALIB. OF STEAM PROBE 2
It permits to calibrate the steam probe 2.
The values shown are expressed in °C or
°F according to the unit of measure set for
the machine. In case of °C, the increase/
decrease is of one unit at a time, while in
case of °F the increase/decrease may also
be of 2 units at a time.
t PRESSURE CALIB.
It permits to calibrate the steam probe of
the steam heater. The values shown are
expressed in dozens of millibars.
t CLOCK CALIB.
It permits to set the machine inner clock as it
may loose the synchronism with a reference
clock on the long term (e.g. a month).
t %&-":&%5"3&
(GRAVIMETRIC VERSION ONLY)
Allow a time interval to be set within which
the machine carries out the tare weight with
a maximum of 5 seconds. In the versions
starting from 2016 the parameter has been
moved to the "Technical settings" section.
t PREINFUSION
It permits to enable/disable the automat-
ic preinfusion during delivery. If ON the
machine injects water into the circuit, it
stops for few seconds to allow water to wet
the coffee capsule and then proceed with
delivery again. It is possible to set the ON
time and the OFF time for the valve opening.
t SERIAL CONNECTION
It permits to enable/disable the serial con-
nection to connect the machine to other
digital equipment, as electronic devices, pc,
etc..
Edition 01 of 08/2017
10.9
SERVICE MANUAL
Menu Principale
Weight calibration
Select group to calibrated
3
Fig. 361