The machine will dispense up to 100 gr.
The value displayed may obviously be slightly
higher.
At this point it is necessary to verify the corre-
spondence between the value displayed above
the group (e.g. 102) and the reference value of
the external scale (e.g. 104). The difference has
to be added to the value shown on the machine,
then set the calibration to 102 gr.