96
Displayed fault
code
System characteristics Cause Measures
F.373 Burner in a fault state Heat transfer too low dur-
ing calibration
Temperature limiter has
shut down.
Ensure adequate heat transfer.
Check circulation pump for faults,
scale or blockages.
Check 3-way diverter valve func-
tion in actuator test. Vent the sys-
tem.
Check function of flow sensor.
Reset the appliance.
F.377 Burner in a fault state Post-processing ionisation
current calibration: Stabili-
sation conditions for post-
calibration not reached
Check gas type setting. If fault re-
curs, replace BCU burner control
unit (see page 109).
Reset the appliance.
F.378 Burner in a fault state Flame loss during stabili-
sation or operating phase
Check gas supply (gas pressure
and gas flow switch).
Check flue gas recirculation.
Check for contamination of ioni-
sation electrode and burner
gauze assembly.
Reset the appliance.
F.379 Burner in a fault state Flame signal not present
or insufficient
Check ionisation electrode con-
necting cable for damage and
ensure it is secure.
Check ionisation electrode, re-
place if necessary.
Reset the appliance.
F.380 Burner in a fault state Flame is lost immediately
after flame formation (dur-
ing safety time)
Check gas supply (gas pressure
and gas flow switch).
Check balanced flue system for
flue gas recirculation.
Check ionisation electrode, burner
gauze assembly:
Clearance to burner gauze as-
sembly
Contamination on electrode
Reset the appliance.
F.381 Burner in a fault state Flame loss during operat-
ing phase
Check gas supply (gas pressure
and gas flow switch).
Check balanced flue system for
flue gas recirculation.
Check ionisation electrode, burner
gauze assembly:
Clearance to burner gauze as-
sembly.
Contamination on electrode
Reset the appliance.
F.382 Burner in a fault state Fault counter has excee-
ded limit.
Reset the appliance. Work through
fault analysis using fault history.
F.383 Burner in a fault state Possible contamination of
gas line
Check gas line for contamination.
Check the gas supply pressure.
Replace gas fan if required.
Reset the appliance.
Troubleshooting
Fault messages (cont.)
5593201
Diagnosis