7. Change the value of one variable, save the OB 1 and transfer it
to the simulator.
ð
According to your settings the process image changes
immediately. The status of your blocks may be displayed
with ‘Block è Monitoring On/Off’.
A further component of the simulator is the PLC mask. Here a CPU is
graphically displayed, which may be expanded by digital and analog
peripheral modules. As soon as the CPU of the simulator is switched
to RUN state, inputs may be activated by mouse and outputs may be
displayed.
1.
Open the PLC mask
with ‘view è PLC mask’.
ð
A CPU is graphically displayed.
2. Double-click to the output module, open its properties dialog and
enter the Module address 124.
3. Switch the operating mode switch to RUN by means of the
mouse.
ð
Your program is executed and displayed in the simulator,
now.
8.3.4 Transfer PLC program to CPU and its execution
1. For transfer to the CPU set the transfer mode to "Target: TCP/
IP-Direct".
2. If there are more network adapters in your PC, the network
adapter may be selected via ‘Extras è Select network adapter
.
3. For presetting the Ethernet data click to [...] and click to [Acces-
sible nodes].
Visualization via PLC
mask
Proceeding
VIPA System 300S WinPLC7
Example project engineering > Transfer PLC program to CPU and its execution
HB140 | CPU-SC | 312-5BE13 | GB | 15-50 175