USER MANUAL
16
NOTE
The filter (E) must be accurately installed onto the position of the housing (G).
6. Open the draining ball valve (A).
Figure 17
TROUBLESHOOTING
Breakdown Probable Cause Remedies
Machine not working:
Indication light not on
Battery connector (9) not connected.
Connect the battery connector
Battery power already exhausted Charge the battery
Warning light (39 and 40)
flashing
Brush motor overloaded
Change to a soft brush to adapt
to the floor being cleaned
Obstruction preventing brush from
spinning
Clear the brush
Brush not working
Brush fuse trip off Reset
Belt slipping
Check belt, adjust tension
Vacuum motor not working Vacuum fuse trip off Reset
Inadequate Vacuum
Recovery tank is full. Drain the recovery tank
Drain hose and squeegee hose not
properly connected
Connect the drain hose and the
squeegee hose
Float filter blocked or inlet blocked
Clean the float filter, check the
float ball
Squeegee dirty or squeegee blade
worn and damaged
Clean and check the squeegee
Recovery tank lid not properly
sealed, or the seal / gasket for
recovery tank damaged
Refit on the lid properly,
replace the recovery tank seal
/ gasket
Water supply to the
brush inadequate
Filter dirty Clean the filter
Squeegee leaving marks
Debris fragments under the
squeegee blade
Remove the fragments
Squeegee blade worn, cracked or
brittle.
Replace the squeegee blade
Balance of squeegee not adjusted Adjust the balance
Filter Mesh Mark