Page 18 Vision Microsystems Incorporated
measurements, fuel system and user connected external inputs
and alerts you if anything is in an alarm condition. When an
alert/warning condition initially occurs, the EC100 annunciates
the condition both visually (via the text display) and audibly (via
an audio voice message). You can acknowledge the alarm by
tapping any key, which mutes it for approximately two minutes.
However the Master Caution enunciator (if connected) remains
lit as long as an alarm condition is present. Any new
alert/warning condition will override the mute period and
immediately annunciate the condition. (Note: If you are in
EMERGENCY CHECKLISTS mode, the warning annunciations
are blocked.
EC100 Checklist Setup
To customize your checklist, you first complete the EVMASTER.XLS
spreadsheet provided according to the onscreen instructions. Next you
will upload the EC100_CHECKLIST.csv file into your VM1000C. To
upload, follow the instructions below:
STEP 1: Make sure you performed the VM1000C RS232 setup.
STEP 2: Connect your PC to the VM1000C checklist serial port.
STEP 3: Activate TERATERM and insure all communication
parameters match VM1000C RS232 parameters.
STEP 4: On VM1000C select UPLOAD CHECKLIST MODE and
select option 1.
STEP 5: On TERATERM select FILE, SEND FILE and open the
EC100_CHECKLIST.csv file located in the C: directory.
STEP 6: Observe that the file is sending and that the VM1000C is
receiving (shows an increasing count in the RPM field).
STEP 7: If the transfer completed successfully, then you will see
the checklist scrolling on the TERATERM screen.
EC100 Checklist voice Prompts setup
To record follow the steps below: