VISUAL
TECHNOLOGY
INCORPORATED, 540
MAIN
STREET,
TEWKSBURY,
MA
01876
Local Echo Mode,
Ps
= 12
Set Mode Sequence:
ESC
[ 12 h
Reset
Mode Sequence:
ESC
[ 12 Q
When set, this mode
causes
transmitted data
to
be
echoed back
to
the screen
within
the
terminal.
When reset
no
local echo
will
occur.
ANSl/VT-52
Mode,
Ps
= 2 (Private)
Set Mode Sequence:
Not
Applicable,
use
ESC
<
Reset Mode Sequence:
ESC
[ ? 2 Q
When reset, this mode
causes,
the
VISUAL
100
to
respond
VT-52
Mode Control Sequences
as
defined in Section 5.3.1.
Cursor Key Mode,
Ps
= 1 (Private)
Set Mode Sequence:
ESC
[ ? 1 h
Reset Mode Sequence:
ESC
[ ? 1 Q
This mode
is
applicable
only
when
the
terminal
is
in ANSI and Alternate Keypad mode.
When set, this mode
causes
the cursor positioning keys
to
generate special
escape
sequences
per Table 4-1.
When reset, the cursor position keys
will
transmit
their
normal ANSI mode sequences per
Table 4-1.
Characters Per
Line
Mode,
Ps
= 3 (Private)
Set Mode Sequence:
ESC
[ ? 3 h
Reset Mode Sequence:
ESC
[ ? 3 Q
When set, this mode conditions the terminal
for
132 column display.
When reset, the terminal
will
use
80
column display.
Scroll Mode,
Ps
= 4 (Private)
Set Mode Sequence:
ESC
[ ? 4 h
Reset Mode Sequence:
ESC
[ ? 4 Q
When set, this mode conditions the termin,al
for
smooth scroll
as
defined in Section 3.2.2.6.
When reset,
the
terminal
is
conditioned
for
jump
scroll
as
defined in Section 3.2.2.6.
42