Resetting MGW Diamond Encoder Settings
The appliance can be reset in one of the following ways:
• A hardware reset
• A software reset.
To reset the MGW Diamond Encoder (Hardware):
On the MGW Diamond Encoder rear panel use the Reset dry contact (located in connector J2) to
connect an external push-button-switch or controller for performing a Reset.
• A short press will restart the appliance.
• A long press (6 seconds) will return the unit to factory settings (erasing all user-stored
channel and network settings).
• Pressing for 2-3 seconds while powering the appliance will re-load the last known good
firmware. To be used only when the appliance does not respond (after a failed
firmware upgrade for example). Restoring to factory will allow to relaunch the upgrade
procedure.
To reset the MGW Diamond Encoder (through the web interface):
1. In the General page, click Factory Reset to reset all values to default factory values.
The Factory Reset window appears:
2. Click Yes to restore the unit to its factory settings.