12 Technical data
Operating voltage ................................. 220 - 240 V/AC, 50 Hz
Internal power consumption ................. <2 W
Max. connected power ......................... 3680 W (230 V/AC, 16 A)
Setup range for overload alarm ............ 0 - 16 A / 0 - 3680 W
Time display .........................................hour (with 12h/24h
.............................................................. mode),
.............................................................. minute, second
Currency for electricity tariff ..................€, $, £ or CHF
Electricity tariff resolution ......................0.001
Overload class ...................................... II
Pollution degree .................................... 2
Operating conditions ............................. 0 °C to +40 °C,
.............................................................. 10% to 90%
.............................................................. relative humidity,
.............................................................. non-condensing
Storage conditions ................................ -10 °C to +70 °C,
.............................................................. 5% to 95%
.............................................................. relative humidity,
.............................................................. non-condensing
Dimensions (H x W x D) ....................... 147 x 71.9 x 70 mm
Weight ..................................................approx. 215 g