Temperatur
Bereich Genauigkeit* Auösung
-40 bis 0 °C
±(2,5% + 5)
1 °C>0 bis +400 °C
>+400 bis +1000 °C ±(3,0% + 5)
-40 bis +32 °F
±(2,5% + 11)
1 °F>+32 bis +752 °F
>+752 bis +1832 °F ±(3,0% + 11)
* ohne Fühlertoleranz
Widerstand
Bereich Genauigkeit Auösung
600,0Ω ±(1,2% + 2) mit REL-Funktion 0,1Ω
6,000kΩ
±(1,0% + 2)
0,001kΩ
60,00kΩ 0,01kΩ
600,0kΩ 0,1kΩ
6,000MΩ ±(1,2% + 2) 0,001MΩ
60,00MΩ ±(1,5% + 5) 0,01MΩ
Überlastschutz 1000 V; Messspannung: ca. 0,4 V