EasyManua.ls Logo

VOLTCRAFT VC-590OLED - Non-contact voltage detection “NCV”

VOLTCRAFT VC-590OLED
156 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
i) Non-contact voltage detection “NCV”
The voltage detector is intended as a means for quick testing and is not a sub-
stitute for contact voltage detection. This method is not permissible for check-
ing the absence of voltages in order to perform work.
The NCV function (non-contact voltage detection) is used to detect the presence of alternating
voltage in conductors. The NCV sensor (1) is located in the tip of the current sensor.
Bring the NCV sensor as close as possible to a conductor. The distance
may not exceed max. 10 mm. If an alternating voltage is detected, the
redNCVLED(3)ashesandabeepsounds.Thedisplayshowsthe
signal strength using 4 arrow symbols.
Due to the high sensitivity of the NCV sensor, the LED may light up in
the case of static charges. This is normal and not a malfunction.
AlwaystesttheNCVrstonaknownACvoltagesourceto
prevent false reads. False reads pose a risk of electric shock.