13. Technical data
Display .......................................................... 6000 counts (digits)
Measuring rate .............................................. approx. 3 measurements/second,
bar graph approx. 3 measurements/second
Measuring procedures V/AC, A/AC .............. True RMS
Test lead length ............................................ approx. 90 cm each
Measurement impedance ............................. >10MΩ(Vrange)
Current clamp opening ................................. max. 30 mm
Test socket spacing ...................................... 19 mm
Automatic power-off ...................................... 0 - 30 minutes (settable in 1 minute intervals)
Power supply ................................................ 3 micro batteries (1.5 V, AAA or LR03)
Operating conditions ..................................... 0 to 30 °C (<80% RH)
>30 to 40 °C (<75% RH)
>40 to 50 °C (<45% RH)
Operating altitude ......................................... max. 2000 m
Storage temperature ..................................... -20°C to +60°C
Weight .......................................................... approx. 265 g
Dimensions (LxWxH) .................................... 228 x 77 x 41 (mm)
Overvoltage category ................................... CAT II 1000 V, CAT III 600 V, Pollution degree 2
Measurement tolerances
Measuring accuracy shown in ± (% reading + indication error in counts (= number of minimum
digits)).Thespeciedaccuracyisvalidfor oneyearatatemperature of+23°C(±5°C) at
arelativehumidityof<80%non-condensing.Temperaturecoefcient:+0.1x(speciedaccu-
racy)/1 °C