Page #1 background image
IMPORTANT NOTE
Version 01/13
DIGITAL MULTIMETER
Item no. 12 23 88 VC1008
Item no. 12 32 94 VC820
Item no. 12 32 95 VC840
Item no. 12 32 96 VC920
Item no. 12 32 97 VC940
Item no. 12 32 98 VC960
Dear Customer,
based on the standard change of IEC 61010-031, the alligator clamps described in the
instructions are no longer included in the delivery.
We ask for your understanding in this matter.
Your VOLTCRAFT team
WICHTIGER HINWEIS
Version 01/13
DIGITALMULTIMETER
Best.-Nr. 12 23 88 VC1008
Best.-Nr. 12 32 94 VC820
Best.-Nr. 12 32 95 VC840
Best.-Nr. 12 32 96 VC920
Best.-Nr. 12 32 97 VC940
Best.-Nr. 12 32 98 VC960
Sehr geehrte Kundin, sehr geehrter Kunde,
aufgrund der Norm-Änderung der IEC 61010-031 sind die in der Anleitung beschriebenen
Krokodilklemmen nicht mehr im Lieferumfang enthalten.
Wir bitten um Ihr Verständnis.
Ihr VOLTCRAFT-Team
Dieser Hinweis ist eine Publikation von Voltcraft®,
Lindenweg 15, D-92242 Hirschau, Tel.-Nr. 0180/ 586 582 7.
Alle Rechte einschließlich Übersetzung vorbehalten. Reproduktionen jeder Art, z. B. Fotokopie, Mikroverlmung, oder die
Erfassung in elektronischen Datenverarbeitungsanlagen, bedürfen der schriftlichen Genehmigung des Herausgebers.
Nachdruck, auch auszugsweise, verboten.
Dieser Hinweis entspricht dem technischen Stand bei Drucklegung.
Änderung in Technik und Ausstattung vorbehalten.
© Copyright 2013 by Voltcraft
®
.
V2_0113_02-SB
This note is published by Voltcraft®,
Lindenweg 15, D-92242 Hirschau/ Germany, Phone +49 180 586 582 7.
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microlming, or the capture in electronic
data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
The note reects the current technical specications at time of print.
We reserve the right to change the technical or physical specications.
© Copyright 2013 by Voltcraft®.
V2_0113_02-SB

Table of Contents

Other manuals for VOLTCRAFT VC1008

Questions and Answers:

VOLTCRAFT VC1008 Specifications

General IconGeneral
TypeDigital Multimeter
Basic accuracy0.5%
Max DC Voltage1000 V
Max AC Voltage750 V
Max DC Current10 A
Measurement CategoryCAT III 600 V
Diode TestYes
Continuity TestYes
DisplayLCD
DC Current Range10A
Frequency Range10Hz - 10MHz
Battery9V
Weight400 g

Summary

IMPORTANT NOTE

DIGITAL MULTIMETER

Lists item numbers for digital multimeters.

Graphic Digital Multimeter VC -1008

OPERATING INSTRUCTIONS

Indicates that this section provides operating instructions.

Introduction

Intended Use

Describes the intended purpose and operating conditions of the product.

Safety Instructions

General Safety Warnings and Symbols

Explains safety symbols and provides general safety advice.

Certification and Insulation Classes

Details CE marking, insulation classes, and voltage categories.

Product Description

Device Components and Display

Describes the multimeter's display, keypad, rotary switch, and sockets.

Scope of Delivery

Included Items

Lists the accessories and components included with the multimeter.

Handling and Startup

Rotary Switch Operation

Explains the functions assigned to each position of the rotary switch.

Description of buttons

Button Functions Overview

Details the functions of each button and the F1-F4 function keys.

Basic settings (Set)

Automatic Deactivation Configuration

Guides on setting the auto power-off timer for battery saving.

Display Brightness and Contrast

Explains how to adjust the screen's background illumination and contrast.

Scope operation

Graphical Display Overview

Shows the main display elements during SCOPE operation.

Scope functions

Auto Set Functionality

Describes the automatic setting for optimal signal display.

Manual Vertical Deflection Adjustment

Details how to manually adjust the vertical deflection scale.

Manual Time Scale Adjustment

Details how to manually adjust the time scale for signal display.

Trigger Function Settings

Explains trigger modes and how to set the trigger threshold.

DMM operation

DMM Operation Safety Precautions

Warns about input limits, damaged leads, and electrical shock risks.

Measuring AC and DC voltage

DC Voltage Measurement Procedure

Step-by-step guide for measuring direct current voltages.

AC/DC Voltage Function Buttons

Explains function buttons for AC/DC voltage measurements.

Resistance measuring/diode test/continuity test

Resistance and Continuity Measurement

Procedure for measuring resistance and performing continuity tests.

Resistance Measurement Precautions

Advises on ensuring clean measurement points for accuracy.

Function Buttons for Resistance/Diode/Continuity

Details function buttons for resistance, diode, and continuity tests.

Frequency measuring/duty cycle

Frequency Measurement Procedure

Step-by-step guide for measuring signal frequency.

Duty Cycle Measurement

Explains how to perform and display duty cycle measurements.

Capacity measuring

Capacitor Measurement Procedure

Step-by-step guide for measuring capacitance of capacitors.

Capacitor Measurement Safety

Warns about discharging capacitors and potential hazards.

Current measuring

Current Measurement Ranges

Introduces current measurement sections and overload protection.

AC/DC Current Measurement (up to 400 mA)

Procedure for measuring direct and alternating currents up to 400 mA.

AC/DC Current Measurement (up to 10 A)

Procedure for measuring direct and alternating currents up to 10 A.

Special functions

HOLD Function

Explains how to freeze the currently displayed measurement value.

Saving and Recalling Measuring Curves

Guides on saving and recalling up to 10 measuring curves in SCOPE mode.

Optical IR Interface

Describes the optical interface and its connection to a PC.

Optional Power Pack Operation

Details how to operate the device using an optional power adapter.

Servicing and cleaning

General Servicing and Calibration

Mentions annual calibration and periodic technical safety checks.

Cleaning Precautions and Methods

Provides safety instructions and guidelines for cleaning the device.

Replacing the fuse

Fuse Replacement Procedure

Step-by-step guide for safely replacing the internal fuses.

Approved Fuse Types

Lists the specific fuse types and ratings permitted for replacement.

Inserting/changing the batteries/accumulators

Battery Installation and Replacement

Instructions for inserting new batteries or changing existing ones.

Battery Removal for Long-Term Storage

Advises removing batteries for long periods or when using power pack.

Disposal of used batteries/accumulators

Battery Disposal Regulations

Explains legal requirements for proper disposal of used batteries.

Disposal

Electronic Waste Disposal

Provides guidelines for disposing of the electronic device as waste.

Troubleshooting

Common Problems and Solutions

Lists common malfunctions and their potential causes and fixes.

Technical Data and Measuring Tolerances

General Technical Specifications

Provides key technical data such as display, resistance, and voltage.

DMM Voltage Measurement Tolerances

Details accuracy, resolution, and overload protection for voltage measurements.

DMM Current Measurement Tolerances

Details accuracy, resolution, and overload protection for current measurements.

DMM Resistance Measurement Tolerances

Details accuracy, resolution, and overload protection for resistance measurements.

DMM Frequency Measurement Tolerances

Details accuracy, resolution, and overload protection for frequency measurements.

DMM Capacity Measurement Tolerances

Details accuracy, resolution, and overload protection for capacity measurements.

SCOPE Operation Tolerances

Details bandwidth, sampling rates, and deflection for SCOPE mode.