REMOTE OPERATION
PM1000+ Power Analyzer User Manual © Voltech 2010 Page 45
"*RST”
Resets the PM1000+ to default settings.
":SCL:VLT <value>”
Sets voltage scaling <value> = scaling
factor 0.0001 to 100000.
":SCL:AMP <value>”
Sets current scaling <value> = scaling
factor 0.0001 to 100000.
":SCL:VLT?”
Returns the current voltage scaling factor.
":SCL:AMP?”
Returns the current amps scaling factor.
":SEL:CLR”
Clears the results selection list.
":SEL:WAT”
Selects watts.
":SEL:VAS”
Selects VA.
":SEL:VAR”
Selects Var.
":SEL:VLT”
Selects Vrms.
":SEL:AMP
Selects Arms.
":SEL:PWF”
Selects PF.
":SEL:VPK+”
Selects Vpk+ (most positive peak).
":SEL:VPK-
Selects Vpk- (most negative peak).
":SEL:APK+”
Selects Apk (most positive peak).
":SEL:APK-
Selects Apk (most negative peak).
":SCL:VCF”
Selects Vcf.
":SCL:ACF”
Selects Acf.
":SEL:WHR”
Selects watt hrs.
":SEL:VAH”
Selects VA hrs.
":SEL:VRH”
Selects VAr hrs.
":SEL:AHR”
Selects A hrs.
":SEL:VDF”
Selects Vdf.
":SEL:ADF”
Selects Adf.
":SEL:FRQ”
Selects frequency.
":SEL:RES”
Selects resistance R.
":SEL:IMP”
Selects impedance Z.