EasyManua.ls Logo

VTI Instruments EX1200 Series - EX1200-6102 Specifications

VTI Instruments EX1200 Series
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.vtiinstruments.com
EX1200-6102 Plug-in Module 127
EX1200-6102
S
PECIFICATIONS
G
ENERAL
S
PECIFICATIONS
C
HANNEL
C
OUNT
17 SPDT
R
ELAY
T
YPE
Electromechanical, fail-safe
M
AXIMUM
S
WITCHING
V
OLTAGE
30 V dc
M
AXIMUM
S
WITCHING
C
URRENT
0.5 A
M
AXIMUM
C
ARRY
C
URRENT
0.5 A
M
AXIMUM
S
WITCHING
P
OWER
10 W
R
ATED
S
WITCH
O
PERATIONS
Mechanical
Electrical
5 x 10
6
1 x 10
5
at full load
S
WITCHING
T
IME
< 5 ms
P
ATH
R
ESISTANCE
< 1 Ω
I
NSULATION
R
ESISTANCE
> 1 x 10
9
Ω
B
ANDWIDTH
(-3
dB)
1.3 GHz (typical)
I
NSERTION
L
OSS
(T
YPICAL
)
100 MHz
500 MHz
1.3 GHz
< 0.2 dB
< 0.5 dB
< 2.0 dB
C
ROSSTALK
(T
YPICAL
)
10 MHz
100 MHz
500 MHz
1.3 GHz
< -70 dB
< -65 dB
< -60 dB
< -55 dB
I
SOLATION
(T
YPICAL
)
10 MHz
100 MHz
500 MHz
1.3 GHz
< -80 dB
< -70 dB
< -65 dB
< -55 dB
VSWR
(T
YPICAL
)
100 MHz
1.3 GHz
< 1.2:1
< 1.5:1
For mating connector, crimp pins, and other accessories, please refer to Appendix B.

Table of Contents