Appendix A: Power Consumption and Weight 167
A
PPENDIX
A
P
OWER
C
ONSUMPTION AND
W
EIGHT
R
EFERENCE
T
ABLES
The following reference table provides power consumption and weight information for the
EX1200 series card. The EX1200 mainframe power specifications are also provided to assist in
determining available power.
P
OWER
S
PECIFICATIONS
A
VAILABLE
P
OWER
EX1202/06/62/66
EX1208/68*
120 W
120 W per segment
*The EX12x8 mainframe is powered by four power supplies and each power supply is used for a finite number of mainframe slots. For more
information, see Appendix B of the EX1200 Series User’s Manual.
M
AXIMUM
C
URRENT
P
ER
R
AIL
1,2
3.3 V 5 V 24 V
EX1202/EX1206
EX1262/EX1266
EX1208/68 (Slots 1 – 5)
EX1208/68 (Slots 6 – 10)
EX1208/68(Slots 11 – 16)
6.00 A 13.420 A 3.320 A
6.00 A 13.410 A 3.074 A
14.99 A 13.582 A 2.950 A
14.99 A 13.362 A 2.950 A
14.99 A 13.355 A 2.950 A
Note
1
: For more information on calculating power consumption, please refer to the Power Consumption discussion in Appendix B of the
EX1200 Series User’s Manual.
Note
2
: These values indicate the maximum current provided by the power supply. This value is limited by the carrying capacity for that rail. See
the Maximum Current Carrying Capacity per Slot specification of the EX1200 Series User’s Manual for more information.
Switch Module
+3.3 V
+5 V
+24 V
Weight
lbs (kg)
Notes
EX1200-2001
0.131 A 0.0037 A* 0 A 1.47 (0.67) *Add 75 mA per relay closure on 5 V
EX1200-2002
0.131 A 0.0037 A* 0 A 0.49 (0.23) *Add 75 mA per relay closure on 5 V
EX1200-2007A
0.135 A 0.0041 A* 0 A 1.05 (0.48) *Add 40 mA per relay closure on 5 V
EX1200-2008H
0.140 A 0.005 A* 0 A 0.76 (0.35) *Add 17 mA per relay closure on 5 V
EX1200-3001
0.135 A 0.0041 A* 0 A 1.01 (0.46) *Add 26 mA per relay closure on 5 V
EX1200-3048
0.129 A 0.0041 A* 0 A 0.39 (0.18) *Add 23 mA per relay closure on 5 V
EX1200-3048S
0.131 A 0.0041 A 0 A 0.28 (0.13) N/A
EX1200-3072
0.129 A 0.0041 A* 0 A 0.35 (0.16) *Add 23 mA per relay closure on 5 V
EX1200-3096
0.140 A 0.005 A* 0 A 0.83 (0.38) *Add 28 mA per relay closure on 5 V
EX1200-3164
0.129 A 0.0041 A* 0 A 0.44 (0.20) *Add 23 mA per relay closure on 5 V
EX1200-4003
0.137 A 0.0040 A* 0 A 0.40 (0.18) *Add 25 mA per relay closure on 5 V
EX1200-4128
0.129 A 0.0041 A* 0 A 0.69 (0.32) *Add 28 mA per relay closure on 5 V
EX1200-4260
0.014 A 0.005 A* 0 A Unavailable *Add 28 mA per relay closure on 5 V
EX1200-4264
0.014 A 0.005 A* 0 A Unavailable *Add 28 mA per relay closure on 5 V
EX1200-5001
0.129 A 0.0041 A* 0 A 0.41 (0.19) *Add 23 mA per relay closure on 5 V
EX1200-5002
0.129 A 0.0041 A* 0 A 0.33 (0.15) *Add 23 mA per relay closure on 5 V
EX1200-5006
0.140 A 0.005 A* 0 A 0.79 (0.36) *Add 28 mA per relay closure on 5 V
EX1200-6101
0.140 A 0.005 A* 0 A 0.93 (0.42) *Add 28 mA per relay closure on 5 V
EX1200-6111
0.140 A 0.005 A* 0 A 0.74 (0.34) *Add 28 mA per relay closure on 5 V
EX1200-6216
0.129 A 0.0041 A* 0 A 0.90 (0.41) *Add 28 mA per relay closure on 5 V
EX1200-6216HV
0.140 A 0.005 A* 0 A 0.94 (0.43) *Add 67 mA per relay closure on 5 V
EX1200-7100
0.131 A 0.0037 A 0 A 0.63 (0.29) Values for carrier only
7102 plug-in
0.131 A 0.0037 A 0.005A* 0.25 (0.12) *Add 140 mA per relay closure on 24 V