EX1200-3048S Plug-in Module 51
TB
Ref Signal
Conn
Pin
TB
Ref Signal
Conn
Pin
TB
Ref Signal
Conn
Pin
TB
Ref Signal
Conn
Pin
T1
CH1_1L 1
T31
CH1_9L 30
T61
CH2_13L 59
T91
CH2_19L 82
T2
CH1_1H 2
T32
CH1_9H 31
T62
CH2_13H 60
T92
CH2_19H 83
T3
CH1_2L 3
T33
CH2_5L 32
T63
CH2_14L 61
T93
UNUSED N/A
T4
CH1_2H 4
T34
CH2_5H 33
T64
CH2_14H 62
T94
SHIELD 84
T5
CH1_COML 5
T35
CH2_6L 34
T65
UNUSED N/A
T95
CH1_20L 85
T6
CH1_COMH 6
T36
CH2_6H 35
T66
SHIELD 63
T96
CH1_20H 86
T7
CH1_3L 7
T37
CH2_7L 36
T67
CH1_15L 64
T97
CH1_21L 87
T8
CH1_3H 8
T38
CH2_7H 37
T68
CH1_15H 65
T98
CH1_21H 88
T9
CH1_4L 9
T39
CH2_8L 38
T69
CH1_16L 66
T99
CH1_22L 89
T10
CH1_4H 10
T40
CH2_8H 39
T70
CH1_16H 67
T100
CH1_22H 90
T11
CH2_1L 11
T41
CH2_9L 40
T71
CH1_17L 68
T101
CH1_23L 91
T12
CH2_1H 12
T42
CH2_9H 41
T72
CH1_17H 69
T102
CH1_23H 92
T13
CH2_2L 13
T43
UNUSED N/A
T73
CH1_18L 70
T103
CH1_24L 93
T14
CH2_2H 14
T44
SHIELD 42
T74
CH1_18H 71
T104
CH1_24H 94
T15
CH2_COML 15
T45
CH1_10L 43
T75
UNUSED N/A
T105
CH2_20L 95
T16
CH2_COMH 16
T46
CH1_10H 44
T76
UNUSED N/A
T106
CH2_20H 96
T17
CH2_3L 17
T47
CH1_11L 45
T77
UNUSED
N/A
T107
CH2_21L 97
T18
CH2_3H 18
T48
CH1_11H 46
T78
UNUSED N/A
T108
CH2_21H 98
T19
CH2_4L 19
T49
CH1_12L 47
T79
UNUSED N/A
T109
CH2_22L 99
T20
CH2_4H 20
T50
CH1_12H 48
T80
UNUSED N/A
T110
CH2_22H 100
T21
UNUSED N/A
T51
CH1_13L 49
T81
CH1_19L 72
T111
CH2_23L 101
T22
SHIELD 21
T52
CH1_13H 50
T82
CH1_19H 73
T112
CH2_23H 102
T23
CH1_5L 22
T53
CH1_14L 51
T83
CH2_15L 74
T113
CH2_24L 103
T24
CH1_5H 23
T54
CH1_14H 52
T84
CH2_15H 75
T114
CH2_24H 104
T25
CH1_6L 24
T55
CH2_10L 53
T85
CH2_16L 76
T115
UNUSED N/A
T26
CH1_6H 25
T56
CH2_10H 54
T86
CH2_16H 77
T116
UNUSED N/A
T27
CH1_7L 26
T57
CH2_11L 55
T87
CH2_17L 78
T117
UNUSED N/A
T28
CH1_7H 27
T58
CH2_11H 56
T88
CH2_17H 79
T118
UNUSED N/A
T29
CH1_8L 28
T59
CH2_12L 57
T89
CH2_18L 80
T119
UNUSED N/A
T30
CH1_8H 29
T60
CH2_12H 58
T90
CH2_18H 81
T120
UNUSED N/A
T
ABLE
4-13:
EX1200-TB104
T
ERMINAL
B
LOCK TO
EX1200-3048S
P
IN
M
APPING
RT1 can be measured by the EX1200 DMM or may be measured using an external instrument. If
an external sensor is used, it must be connected to T163 (L_VS) and T164 (H_VS). The user may
also choose to use a sensor other than the on-board thermistor. To do so, connect the sensor using
T161 (RL_I) and T162 (RH_I). Note that CH1_1L (T1) and CH1_1H (T2) must be dedicated to
making temperature measurements once P2 is configured.