4-38 BA EZ26 en/us* 1.0 * EZ26_01_400.fm
4 Putting into operation
1. Insert the starting key.
2. Turn the starting key to position 1.
3. Indicator lights A – C are illuminated for a few seconds.
➥ If an indicator light does not function, contact a Wacker Neuson service
center.
4. Turn and hold the starting key in position 2 until the indicator light for
pre-heating (A) goes out.
➥ The indicator lights engine oil pressure (B) and alternator charging
(A) are illuminated.
5. Turn the starting key to position 3 until the engine runs.
➥ All indicator lights go out.
➥ If the engine does not start after 20 seconds:
6. Interrupt the start procedure and repeat it after two minutes.
➥ If the engine still does not start after a few tries, contact a Wacker
Neuson service center and have the error rectified.
7. Release the starting key as soon as the engine runs.
Warm-up phase of vehicle
After the engine has started, allow it to warm up at slightly increased idling
speed until the coolant reaches its operating temperature of about 80 °C
(176 °F).
Do not let the vehicle warm up at standstill.
Check for unusual noise, exhaust color, leaks, malfunctions, or damage.
In case of malfunctions, damage, or leaks:
Secure the vehicle, park it and find out the cause for the damage and
have it repaired.
Fold up the control lever base after shutting off G the engine.