EPG-SPRINT / EPG-SPRINT X
P_01283
HIGH
60 ms (±5 ms)
MSB LSB
HIGH
60 ms (±5 ms)
LOW
>= 50 ms
LOW
20 ms (±5 ms)
LOW
>5 ms
20ms
(±5ms)
20ms
(±5ms)
P_01284
SERVICE MANUAL
VERSION 09/2017 ORDER NUMBER DOC2309350
A simple serial protocol is used to transfer a 6-bit piece of information. First, a start sequence
must be transmitted, followed by the 6 data bits and a stop sequence. The MSB is transmitted
as the  rst data bit.
The expanded transfer protocol with a data bit sequence for the selection of all 50 recipes.
This transfer protocol must be selected via con guration parameter C16 = ON.
Start sequence
6 x data bits
Stop sequence
Depending on information "0" or "1", a data bit appears as follows:
Bit length: 60 ms (±5 ms) Bit length: 60 ms (±5 ms)
Data bit "0" Data bit "1"
12.4.2 SELECTION WITH TRANSFER PROTOCOL

Table of Contents