72
Status
Code
Name Description
43
Unused
44
Sensor Input Failure
Sensor input failure or sensor board alarm.
45
Sensor Fault Error
Sensor value outside of fault limits.
46
Sensor Range Alarm
Sensor value outside of range limits.
47
Relay Cycle Delay
Relay state change delayed by minimum cycle time setting.
48
Sensor Normal
Sensor is running in normal operation.
49
Sensor Initializing
Sensor input is initializing.
50
Sensor Default Temp
Sensor using default temperature instead of sensor value.
51
Alarm Relay: Open
Alarm Output relay closes on an alarm.
52
Alarm Relay: Closed
Alarm Output relay opens on an alarm.
53
Probe Wash: Relay Off
Probe Wash in progress for input sensor.
54
Disabled
Object is disabled.
55
Duty Cycle: Off
Relay is off due to duty cycle settings.
56
VI Calculation Error
Calculation error while evaluating a virtual input.
57
Output On Delay
Relay is off waiting for on delay to expire.
58
Output Off Delay
Relay is on waiting for off delay to expire.
59
DI Flow Verify: Off
DI Flow Monitor reports an error, output is forced off.
60
DI Flow Verify: Auto
DI Flow Monitor reports an error, output is in auto mode.
61
Output PID Saturated: High
PID integral hold due to output saturated at 100%.
62
Output PID Saturated: Low
PID integral hold due to output saturated at 0%.
63
Output Lead Lag
Lag is controlling (or being controlled) in automatic mode.
64
DI Flow Verify: Reprime
DI Flow Monitor reports an error, output is forced on.
65
Spike Onset
Spike onset climb active before reaching spike setpoint.
66
Spike Event: On
Spike onset value achieved, event in progress, output on.
67
Spike Event: Off
Spike onset value achieved, event in progress, output off.
68
Stabilizing
Sensor input is in a stabilization delay
69
Circuit Test
Corrosion Sensor circuit self-test in progress
70
Cable Test
Corrosion Sensor cable test in progress
71
Circuit Cal
Corrosion Sensor circuit calibration in progress
72
Polarization
Corrosion Sensor polarization measurement in progress
73
Imbalance
Corrosion Sensor imbalance measurement in progress
74
Resistance
Corrosion Sensor solution resistance measurement
75
Enabled
Ethernet or WiFi communications enabled
76
Invalid Config
WiFi configuration settings invalid
77
Connecting
WiFi connection in progress
78
Network Not Found
WiFi infrastructure network not available
79
Invalid Key
WiFi security key for infrastructure network invalid
80
Unable To Connect
WiFi unable to connect to infrastructure network
81
Connected
WiFi infrastructure network connection successful
82
Ad-Hoc Idle
WiFi ad-hoc mode available and not currently connected
83
Ad-Hoc Connected
WiFi ad-hoc network connection successful

Table of Contents