System components:
Temperature control valve (HT)4V01-
1
Circulating pump (preheater)4P04
Temperature control valve (LT)4V03Stand-by pump (LT)4P05
Temperature control valv (charge air)4V09Transfer pump4P09
Circulating pump (HT)4P14
Circulating pump (LT)4P15
SizePipe connections:
DN150HT-water inlet401
DN150HT-water outlet402
OD15HT-water air vent404
DN150HT-water from preheater to HT-circuit406
DN150HT-water from stand-by pump408
OD22HT-water drain411
OD15HT-water air vent from CAC416
DN150LT-water inlet451
DN150LT-water outlet452
OD15LT-water air vent from air cooler454
DN150LT-water from stand-by pump457
LT-water air vent483
DBAD209883 9-11
9. Cooling Water SystemWärtsilä 46DF Product Guide

Table of Contents