Installation manual
43
487 14 59 11 - TD30 TD50 TD75 US
Electric installation
Important
The sizes of the fuse group and the effect are shown on the
following page.
The tumble dryer must be equipped with supplementary
protection in accordance with heavy current regulations.
For calculation of the connection cable dimension, please
refer to local guidelines.
Connecting the cable
1. Demount cover plate A, fig. 1.
2. Pass the feeder cable through cable gland**, fig. 1.
3. Connect the feeder cable as illustrated.
4. Remount cover plate A.
5. Function check the dryer.
The function check is described in the back of this manual.
It is your responsibility to have ALL electrical connections (including grounding)
made by a properly licensed and competent electrician to assure that the electric
installation is adequate and conforms with local and state regulations or codes.
In the absence of such codes, ALL electric connections, material, and workmanship
must conform to the applicable requirements of the NATIONAL ELECTRIC CODE
ANSI/NFPA NO. 70-
or the CANADIAN ELECTRICAL CODE, CSA C22.1 - both
the latest edition.
A separate circuit serving each dryer must be provided. The dryer must be
connected to copper wire only. DO NOT use aluminum wire which could cause a fire
haard.