8 Pump specifications
8.1 Specification ratings
Operating temperature 5C to 40C (41F to 104F)
Storage temperature 630: -25C to 65C (-13F to 149F)
Humidity (non-condensing) 80% up to 31C (88F) decreasing linearly to 50% at 40C (104F)
Maximum altitude 2000m (6560ft)
Power Rating 630: 250VA
Supply voltage 100-120V/200-240V 50/60Hz 1pH (Subject to regional cord sets and
supply)
Maximum voltage fluctuation +/-10% of nominal voltage. A well regulated electrical mains supply
is required along with cable connections conforming to the best
practice of noise immunity.
Full load current 630: <1.1A @ 230V; <2.2A @ 115V
Fuse rating T2.5AH250V (5x20mm)
Installation category
(overvoltage category)
II
Pollution degree 2
IP 630: IP31 to BS EN 60529, if supplied with N module then IP66 to
BS EN 60529. Equivalent to NEMA 4X to NEMA 250 *(indoor use -
protect from prolonged UV exposure)
dB rating 630: < 70dB (A) @ 1m
Control ratio 630: 0.1-265rpm (2650:1)
Maximum speed 630: 265rpm
8.2 Weights
630 Drive only + 620R, 620RE + 620RE4 + 620L, 620LG
IP31 16.5kg 36lb 6oz 19.6kg 43lb 3oz 20.1kg 44lb 5oz 24.3kg 53lb 9oz
IP66 17.4kg 38lb 8oz 20.5kg 45lb 3oz 21.0kg 46lb 5oz 25.2kg 55lb 9oz
m-630un-en-08 13