If the delivered dose differs from the volume required, the percentage may be adjusted within the limits
50% to 150% of the master dose. Use the / keys to alter the percentage. The new dose size is displayed
as a percentage on the home screen.
107%
0%
If STOP is pressed during dosing, the pump stops. Pressing START will resume, or discard, the
interrupted dose depending on the settings in "Resume interrupted doses" on page85.
22 EtherNet/IP™ mode
22.1 Configure EtherNet/IP Settings
Configure the settings to suit your network. The following is an example of a static IP address:
Setting Value
DHCP Enable Off
IPAddress 192.168.001.012
Subnet mask 255.255.255.000
Gateway address 192.168.001.001
90 m-630un-en-08