Summary

Declaration of Conformity

Warranty and Conditions

Warranty Conditions

Conditions for warranty validity, including service and connections.

Warranty Exceptions

Items and conditions excluded from the warranty coverage.

Unpacking and Storage

Packaging Disposal and Inspection

Instructions for safely disposing of packaging and inspecting components.

Components, Accessories, and Storage

List of supplied parts, optional accessories, and storage recommendations.

Information for Returning Pumps

Safety Notes

Pump Specifications

Technical Specifications

Detailed technical data including flow range, power, and dimensions.

Applicable Standards

Electrical, safety, and EMC standards for AC and DC power supplies.

Dimensions

Physical dimensions of different qdos pump models.

Weights

Weight specifications for various qdos models and configurations.

Good Pump Installation Practice

General Recommendations

Key advice for safe and effective pump installation and setup.

Dos, Donts, Pressure, and Dry Running

Best practices, prohibitions, pressure limits, and dry running behavior.

Connecting to a Power Supply

AC Mains Power Supply Connection

Guidance for connecting the pump to an AC power source.

DC Power Supply Option

Information on connecting to various DC power sources.

Start-up Checklist

Automatic Control Wiring (No Relay Modules)

Input Pin Assignments

Details of input pin functions and wiring connections.

Output Pin Assignments

Details of output pin functions and wiring connections.

Relay Module Control Wiring

Module Cover and Wiring

Procedures for relay module cover removal, refitting, and terminal wiring.

Wiring Terminal Connectors

Instructions for wiring the terminal connectors on the relay module.

24 V Relay Module PCB Connectors

Diagrams and explanations of 24V relay module PCB connectors.

110 V Relay Module PCB Connectors

Diagrams and explanations of 110V relay module PCB connectors.

PROFIBUS Control Wiring

PROFIBUS Installation

Guidelines for installing the pump on a PROFIBUS network.

PROFIBUS Pin Assignments

Pinout details for PROFIBUS connections at the pump.

Switching On Pumps (Manual;PROFIBUS;Universal)

Initial Power-Up Procedure

First-time power-up, language selection, and initial defaults.

Subsequent Power Cycles

Procedure for powering up the pump after initial setup.

Switching On (Remote)

Pump Operation

Remote Pump Operation

How the remote pump operates via analog signal input.

Manual and PROFIBUS Operation

Keypad functions for manual, PROFIBUS, and Universal modes.

Manual Mode Operation

PROFIBUS Mode and Settings

PROFIBUS Installation and Address

Enabling PROFIBUS and setting the station address.

PROFIBUS Communication Errors

Troubleshooting communication issues and using the GSD file.

PROFIBUS GSD File

Information about the PROFIBUS GSD file for integration.

User Parameter Data

Setting user parameters via the GSD file for PROFIBUS.

PROFIBUS Data Exchange

Details on PROFIBUS data exchange, parameters, and diagnostics.

Device-Related Diagnostic Data

Information on device-specific diagnostic data.

Channel-Related Diagnostic Data

Details on channel-specific diagnostic data.

Flow Calibration Mode

Analog 4-20 mA Mode

Calibrating the Pump for 4-20 mA Control

Procedure to calibrate the 4-20mA input for Universal+ models.

Contact Mode

Contact Settings and Operation

Configuring contact mode and its operating parameters.

Contact Operating Mode

How the pump operates in contact mode.

Fluid Recovery Mode

Remote Fluid Recovery

Enabling and operating remote fluid recovery.

Main Menu Navigation

Fluid Level Monitor

Monitoring fluid levels and setting alerts.

Security Settings

Configuring keypad lock, PIN protection, and auto restart.

General Settings

Adjusting flow units, asset number, pump label, and language.

Control Settings

Adjusting speed limits, resetting counters, and configuring outputs.

Help Screens

Accessing help screens for information and support.

Status LEDs

Troubleshooting

Leak Detection

What to do when a leak is detected by the pump.

Error Codes

List and explanation of pump error codes and suggested actions.

Error Indication (Remote)

How LED icons indicate pump status and errors remotely.

Technical Support

Drive Maintenance

Pumphead Replacement (qdos 30)

Connecting Interface Tubing

Instructions for connecting tubing to the pumphead.

Pumphead Replacement (qdos 20, 60, 120)

Connecting Interface Tubing

Instructions for connecting tubing to the pumphead.

Ordering Information

Pump Part Numbers

Codes and structure for ordering specific pump models.

Spares and Accessories

List of available spare parts and accessories with part numbers.

Performance Data

Detailed performance specifications, conditions, and curves.

Trademarks

Publication History

Watson-Marlow qdos30 Specifications

General IconGeneral
Pump TypePeristaltic
Power Supply24V DC
Self-primingYes
Drive TypeElectric
ControlManual or remote
MaterialsPolypropylene
Operating Temperature Range0°C to 40°C