22.8 Pump parameters
Setting parameters
To set a parameter to a new value:
Type a value into the field or click on the check box (depending on the parameter type)
Click 'set' to store the new value or click 'refresh' to cancel the change
Up to 10 parameters are displayed per page. Use the < and > buttons to navigate between pages
The following parameters can be set by the user.
Param
No.
EDS Values Read/Write
Default
Value
(EDS)
Parameter
Range
Comments
1 SetFlowCal Write 15120
1 -
2147483647
Use to set the tube flow
calibration value. The flow
calibration value is set in
μL. For more information
on flow calibration
see"Flow calibration "
on page73
2 SetSpeed Write 100 1 - 2200
Speed is set in Deci RPM.
Max speed depends on
head type.See
"PumpHead" on
page108.
3 SetSpeedLimit Write 2200 1 - 2200
Speed is set in Deci RPM.
Max speed depends on
head type. See
"PumpHead" on
page108.
4 SetFailsafeSpeed Write 100 1 - 2200
If the failsafe is enabled
the pump will run
continuously at the
selected speed in the
event of a
communications loss.