Display settings 40 Markoprint Integra Vivid
Page 37 of 45 GB
Status Item at right side
In this menu the status display can be changed. E.g. from speed to prints/sec, prints/min
and prints/hour.
Maximum value for right item
In this menu the maximum value of the right status display can be changed. E.g.: for a
conveyor belt, using a rotary encoder, that can reach up to 30 m/min, the maximum value
is set to 30.
Or a production machine that can reach up to 500 prints per minute, the maximum value
is set to 500.
The changes made are shown on the right side of the display