Quick Parameter Reference .
2 | ECW500
Modbus
Address
Description
Adjustable Range
Factory
Setting
Setting
Proper
.
30014
Modbus timeout
100 to 9950 ms
500 ms
Anybus
31114
Reset Anybus Module
0 = Disable, 1 = enable
0
31124
Anybus Ethernet IP Field 1
0 a 255
192
31126
Anybus Ethernet IP Field 2
0 a 255
168
31128
Anybus Ethernet IP Field 3
0 a 255
0
31130
Anybus Ethernet IP Field 4
0 a 255
10
31132
Anybus Ethernet Mask Field 1
0 a 255
255
31134
Anybus Ethernet Mask Field 2
0 a 255
255
31136
Anybus Ethernet Mask Field 3
0 a 255
255
31138
Anybus Ethernet Mask Field 4
0 a 255
0
31140
Anybus Ethernet Gateway Field 1
0 a 255
192
31142
Anybus Ethernet Gateway Field 2
0 a 255
168
31144
Anybus Ethernet Gateway Field 3
0 a 255
0
31146
Anybus Ethernet Gateway Field 4
0 a 255
1
31148
Anybus DHCP Configuration
0 = Disable, 1 = Enable
0
31150
Anybus Mapped Reading Address 0
30002 a 49998
39998
31152
Anybus Mapped Reading Address 1
30002 a 49998
39998
31154
Anybus Mapped Reading Address 2
30002 a 49998
39998
31156
Anybus Mapped Reading Address 3
30002 a 49998
39998
31158
Anybus Mapped Reading Address 4
30002 a 49998
39998
31160
Anybus Mapped Reading Address 5
30002 a 49998
39998
31162
Anybus Mapped Reading Address 6
30002 a 49998
39998
31164
Anybus Mapped Reading Address 7
30002 a 49998
39998
31166
Anybus Mapped Reading Address 8
30002 a 49998
39998
31168
Anybus Mapped Reading Address 9
30002 a 49998
39998
31170
Anybus Mapped Reading Address 10
30002 a 49998
39998
31172
Anybus Mapped Reading Address 11
30002 a 49998
39998
31174
Anybus Mapped Writing Address 0
30000 a 39998
30000
31176
Anybus Mapped Writing Address 1
30000 a 39998
30000
31178
Anybus Mapped Writing Address 2
30000 a 39998
30000
31180
Anybus Mapped Writing Address 3
30000 a 39998
30000
31182
Anybus Mapped Writing Address 4
30000 a 39998
30000
31184
Anybus Mapped Writing Address 5
30000 a 39998
30000
31186
Anybus Mapped Writing Address 6
30000 a 39998
30000
31188
Anybus Mapped Writing Address 7
30000 a 39998
30000
31190
Anybus Mapped Writing Address 8
30000 a 39998
30000
31192
Anybus Mapped Writing Address 9
30000 a 39998
30000
31194
Anybus Mapped Writing Address 10
30000 a 39998
30000
31196
Anybus Mapped Writing Address 11
30000 a 39998
30000
31198
Anybus device node ID
0 a 255
63
31200
Anybus baud rate
0 = 125 kbps
3
1 = 250 kbps
2 = 500 kbps
3 = auto
31202
Anybus Modbus timeout
100 a 9990 ms
500 ms
31204
Enable DCP
0 = Disable, 1 = Enable
0
31214
Status Word
0 a 127
RO
31216
Command Word
0 a 32767
0
Ethernet
30258
Ethernet IP Field 1
0 a 255
192
30260
Ethernet IP Field 2
0 a 255
168
30262
Ethernet IP Field 3
0 a 255
0