6.6 Water replacement
During the installation of the machine, the Qualied
Technician must replace the water contained in the hy-
draulic circuits by following these steps:
• when installation is complete, the appliance has to
be started, brought to the nominal working condi-
tion and left for 30 minutes in the "ready to operate"
condition;
• afterwards, the appliance has to be turned o and
emptied of the rst water introduced in the whole hy-
draulic circuit, to eliminate possible initial impurities;
• then, the appliance must be loaded and brought to
the nominal working conditions;
• turn o the machine again and empty the water
circuit;
• turn on the machine, then load it and bring it to the
nominal working conditions;
• when the "ready to operate" status is reached, carry
out continuous dispensing for each coee unit, in or-
der to release at least 0.5 liters from the coee circuit.
• continuously release steam for at least 1 minute for
each steam dispensing point.
If the machine remains inactive for a time longer than 1 week, the
Qualied Technician must renew 100% of the water contained in
the hydraulic circuit, as indicated above.
• Before using the machine, run dry deliveries with the lter
holder attached for a few seconds to release any air which may
be in the circuit, so that the dispensing groups are completely
heated;
• before using the machine, dispense a few servings of coee to
test the grinding and to check the operating pressure of the
machine
• during dispensing of coee, do not remove the lter holder
from the brewing.
7. MACHINE INFORMATION
The machine information is available on display:
• select the bar on the right side of the display;
• select the menu key
;
• select the information key
.