44 of 76
TECHNICIANS manual
8.17 Boiler eciency
This section allows to check the eciency of the
boilers. The comparison between the dierent param-
eters over time allows to assess the state of the boiler
operation:
• for each group boiler: time necessary to raise the
temperature by 1 °C - last measurement;
• for each group boiler: time necessary to raise the
temperature by 1 °C - rst measurement;
• for each group boiler: temperature raised in 1 minute
- last measurement;
• for each group boiler: temperature raised in 1 minute
- rst measurement;
• for the services boiler: time necessary to raise the
temperature by 1 °C - last measurement;
• for the services boiler: time necessary to raise the
temperature by 1 °C - rst measurement;
• for the services boiler: temperature raised in 1 minute
- last measurement;
• for the services boiler: temperature raised in 1 minute
- rst measurement;
To reset the values to the factory defaults, select the
button
.
To switch from one page to another, select the key
.