Wega MyConcept EVDP 2GR - Programming menu overview

Wega MyConcept EVDP 2GR
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29 of 76
TECHNICIANS manual
ENGLISH
8.2 Programming menu
From the two pages of the menu you can ac-
cess the complete programming of the machine.
Below is a summary of the programming sec-
tions, the parameters involved, and the planned
operations.
The following paragraphs list all the operations
in detail.
1 - maintenance report
maintenance cycles type A-B-C
date of the next maintenance
water consumption (lt)
grind wear (kg)
energy saved (kWh)
reset
set date
reset
reset
reset
3- washes
date of last wash
enable automatic wash
wash at each start-up
number of washing cycles
washing time
rinsing time
minimum interval between 2 starting washes
time of automatic washing
number of washes performed
view
enable
enable
set (no.)
set (min)
set (sec)
set (hours)
set time
reset
4 - dispensing check
view time
monitor ow
view temperature
enable
enable
enable
7 - recipe management
recipe name
set group boiler
set group
grinding neness
set name
set (°C)
set (°C)
set
8 - alarm history
alarms by date
alarms by type
reset
view
5 - coee
set group N
set group N boiler
set (°C)
set (°C)
6 - language
language set language
2 - service tuning
boiler pressure
boiler temperature in energy saving
cup heater temperature
boiler boost set
boiler boost duration
set (bar)
set (°C)
set (°C)
set (bar)
set (min)
9 - lters
regeneration threshold
water consumption
set (lt)
view
10 - parameter list
parameters N set
maintenance threshold type A-B-C
cycles to reach the threshold A-B-C
date of next maint. threshold A-B-C
days until maintenance
short-normal-long dose
double short-normal-long dose
continuous dispensing dose
grinds threshold
set no. cycles
view
view
view
set (gr)
set (gr)
set (gr)
set (kg)
11 - maintenance threshold
update keypads
update base
load slide
set parameters
save parameters
import languages
update
update
load
load
save
import
12 - USB
time for delta 1 °C last measurement gr-boil
degrees in 1 minute last measurement gr-boil
time for delta 1 °C rst measurement gr-boil
degrees in 1 minute rst measurement gr-boil
time for delta 1 °C last measurement gr-boil
view
view
view
view
view
15 - boiler eciency
reset user parameters
reset technician parameters
reset manufacturer parameters
load
load
load
17 - reset parameters
temperatures card-boiler-group
pump-boiler pressure
boiler levels
ambient humidity
inlet-group ow
view
view
view
view
view
13 - inspections
no. deliveries per dose reset
14 - counters list