WEIGHTECH USA Weighing indicator WT3000-IR ABS Technical manual
Wt3000irabs v20151126
19
Important: when this value is equal to 0 the automatic transmission
will be disabled.
rS1-08
Output condition
ALL-P
All status transmission
StP-P
StP-P
Transmission only while stable weight applied
StoL-P
Transmission only while stable weight applied or OL status
rS1-09
Configuration of
the weight data
size
Six
6 digits
Six
SEvEn
7 digits
rS1-10
RTC
configuration
yy/mm/dd
Date setting
---.---
hh/mm/ss
Time setting
rS1-11
Date format
configuration
y_m_d
Year/Month/Day
y_m_d
d_m_y
Day/Month/Year
rS1-12
Address setting
Id 00
Indicator address
Only for RS-485
Id 00
rS1-13
Empty spaces at
the end of
transmission
setting
n 00
Configuration of “LF” asc characters sent after the transmission.
Only for RS1-03 = Fm10 or Fm11
n 00