IN.CLEAR
Bromine based water sanitization system for spa
1. Fill the spa with water.
2. Begin heating the water to your desired temperature.
3. Balance your water parameters (see info in your user guide
regarding water chemistry for spa: total hardness, alkalini-
ty, pH).
4. Start main pump and add BromiCharge™ slowly into the
warm water, 0.54 kg for every 378 liters (1.2 lbs per every
100 gallons) of water.
5. Turn on the in.clear system by pressing and holding the
on/off button for 2 seconds, until your display lights
up. Refer to your user manual for information on achieving
the proper BromiCharge™ quantity.
6. Now you’re ready to calibrate your in.clear settings. There
are 2 settings, Maintenance and Boost.
7. Maintenance: Your Maintenance value was set at the fac-
tory. It should read “5” to start. Using your spa while you’re
establishing the residual will slow the process. Be patient.
Check your bromine level each day with a test kit. Your
goal is a residual bromine bank of 3 – 5 ppm. If the bro-
mine content of your water is less than 3 ppm, press and
hold the Maintenance key for 2 seconds and increase
the Maintenance setting by 1 or 2 increments with the up
arrow . Repeat daily until your bromine level stabilizes
at 3 – 5 ppm.
IMPORTANT FOR THE STAND ALONE VERSION: Make sure
your spa is filtering the water at least 8 hours per day. The
in.clear only creates bromine when the filter pump is running.
8. Boost: Every time you use the spa, press Boost . Boost
runs a clean-up cycle that returns your residual bromine to
the proper level. You should run Boost every time you use
the spa. Press Boost key . Set the Boost level by using
the up and down arrow to select the number of
bathers that use the spa (i.e., 2 users = 2, and so on). With
the proper Maintenance level setting, and consistent use
of the Boost mode, your spa will be ideally maintained.
Refer to our web site www.geckoalliance.com/inclear for
detailed information about the operation of the in.clear.
START UP PROCEDURE
(Instruction video: www.geckoal.com/inclear)
On/Off Maintenance
OPTIONAL ACCESSORIES IN.CLEAR
48