Decommissioning for a period of disuse
20
18 Decommissioning for a period of disuse
If the machine needs to be out of operation for a long duration (holidays, seasonal business), proceed as
follows:
Empty the machine using the self-cleaning programme ( 9.1.2).
Clean the machine ( 9.1.3 and 9.1.4).
Leave the hood open.
Close the on-site water stop cock.
Switch off the local mains disconnector.
Store detergent and rinse aid containers frost-free.
If the machine is in a place that is not frost-free:
Instruct an authorised service technician to make the machine frost-resistant.
The engineer must drain the boiler, pump, solenoid valve and any chemical dosing system attached to
the machine.
19 Recommissioning after a period of disuse
After extended periods of disuse, proceed as follows:
Open the on-site water stop cock.
Reinstall detergent and rinse aid containers.
Switch on the local mains disconnector.
Switch on the machine.
If the machine was in a place that was not frost-free:
After extended periods of disuse, the machine must be completely climatised (at least 24 hours at 25 °C). If
this requirement is met:
Contact an authorised service technician to put the machine back into service.
20 Technical data
Voltage
see rating plate
Total connected load
Fuse
Minimum flow pressure
15.1
Maximum inlet pressure
Water inlet temperature
Dimensions