1139300 Shadow 8 User Manual
I-2 Index
inputs, wiring to control
AC power
,2-37
External Device Monitoring (EDM),2-41
main optic heads,2-31
–K–
key switch. See Program/Run/Start key switch,
Program Off/On key switch
–L–
LED indicators
Individual Beam Indicators (receiver)
,3-1
operating state indicators (main receiver),3-1
power indicator (control),3-2
safety relay indicators (control),3-2
status indicator (main transmitter),3-1
lens(es), checking and cleaning,4-7
–M–
main board, location of components,2-32
main optic heads
wiring directly to WPC
,A-1
wiring to control,2-31
mirrors
dimensions
,2-24
using for multiple-sided guarding,2-22
mounting brackets. See brackets
mounting location (Shadow 8 heads),
selecting
,2-15
MPCE. See External Device Monitoring (EDM)
inputs
–O–
object sensitivity
and blanking windows
,2-10
relationship to depth penetration factor,2-7
using in ANSI safety distance formula,2-7
Occupational Safety and Health Administration
(OSHA)
extracts of regulations
,D-1
formula for calculating safety distance,2-4
operating mode, setting,2-46, 3-3
operating state LED indicators (main receiver),3-1
optic heads
adding extension units
,2-59
connecting extension units,2-35
dimensions,2-19
mounting loosely,2-28
removing extension units,2-60
wiring main units directly to WPC,A-1
wiring main units to control,2-31
option switches, setting in control box,2-45
OSHA. See Occupational Safety and Health
Administration (OSHA)
outputs
wiring auxiliary output(s)
,2-44
wiring N/O stop relay outputs,2-40
wiring stop relay outputs to a Programmable
Logic Controller (PLC)
,2-42
wiring stop relay outputs to a Wintriss clutch/
brake control
,2-43
–P–
pass-through protection, providing,2-12
perimeter guarding, increasing safety distance
for
,2-10
PLC. See Programmable Logic Controller (PLC)
PMA. See Precision Metalforming Association
(PMA)
power requirements, AC power
,2-37
Precision Metalforming Association (PMA),
interpretation of OSHA regulations
,D-1
Presence Sensing Device Initiation (PSDI), special
requirements for
,2-14
Program Off/On key switch
location on Shadow 8 control box
,1-5
location on WPC front panel,A-1
using to program a fixed blanking window,3-6
Program/Run/Start key switch
location on Shadow 8 control box
,1-5
location on WPC front panel,A-1
using to clear a light curtain fault,3-2
using to program a fixed blanking window,3-6
using to reset the light curtain, 1-10, 3-2, 3-3
Programmable Logic Controller (PLC), wiring stop
relay outputs to
,2-42
PSDI. See Presence Sensing Device Initiation
(PSDI)
–R–
receiver. See optic heads
reflective surface interference, preventing
,2-25
relays
checking for failure
,4-10
replacing relay board,4-11
response time (Shadow 8)
using in ANSI safety distance formula
,2-7
using in OSHA safety distance formula,2-5
–S–
safety distance
calculating using ANSI formula
,2-6
calculating using European formulas,2-8
calculating using OSHA formula,2-4
increasing for blanking windows,2-10
increasing for perimeter guarding,2-10
providing pass-through protection within,2-12
safety relay outputs, wiring,2-39
safety relays. See stop relay outputs, relays
shock mounts
mounting control with
,2-29
mounting optic heads with,2-28
side guards. See guarding
specifications
,1-13
stands. See floor stands

Table of Contents