Shadow 8
®
Safety Light Curtain
1139300
Rev. K March 2015
UserUserUser
ManualManualManual
User
Manual
Tech Support Hotline 800-586-8324 8-5 EST
www.wintriss.com
Wintriss Controls Group, LLC
100 Discovery Way
Unit 110
Acton MA 01720 USA
Phone (800) 586-8324
Fax (978) 263-2048
PRINTED IN USA
®
®

Table of Contents

Questions and Answers

  • A
    April CalderonSep 13, 2025
    What to do if EDM circuit was in wrong state during power-up in Wintriss Shadow 8?
    • N
      Natasha NelsonSep 13, 2025
      If the EDM circuit was in the wrong state during power-up on your Wintriss Security Sensors, check and correct EDM wiring.
  • B
    Brandy PhillipsAug 25, 2025
    Why Shadow 8 Control Box Power LED dims and blinks in Wintriss Security Sensors?
    • W
      williamlewisAug 25, 2025
      If the Shadow 8 Control Box or WPC Power LED dims and blinks on your Wintriss Security Sensors, turn off the power and unplug the Main Transmitter. Then, turn the power back on. If the Power LED still dims and blinks, a Receiver segment is defective. If the Power LED behaves normally, a Transmitter is at fault.
  • H
    Hayden StoneAug 25, 2025
    What to do if Machine Run/Stop and Blanking Active LEDs flash simultaneously in Wintriss Shadow 8?
    • C
      Carla JonesAug 26, 2025
      If the Machine Run/Stop and Blanking Active LEDs flash simultaneously on your Wintriss Security Sensors, turn the Program/Run/Start key to START to clear the error. Then, reprogram the fixed blanking window, reducing the number of blanked beams.
  • D
    Debbie CookSep 23, 2025
    What to do if there is Error in segment 4 during operation of Wintriss Security Sensors?
    • C
      Charles RamirezSep 23, 2025
      If there's an error in segment 4 during operation of your Wintriss Security Sensors, check connections to segment 4 and replace segment 4 with a known good segment.
  • N
    Nathan Cruz Jr.Sep 14, 2025
    What to do if number of segments in system has been reduced in Wintriss Security Sensors?
    • T
      Taylor JacksonSep 14, 2025
      If the number of segments in the system has been reduced in your Wintriss Security Sensors, add required segment(s) or program system for current configuration.
  • N
    Nicole CollierSep 23, 2025
    What to do if there is Error in segment 2 during operation of Wintriss Shadow 8?
    • J
      James SullivanSep 23, 2025
      If there's an error in segment 2 during operation of your Wintriss Security Sensors, check connections to segment 2 and replace segment 2 with a known good segment.
  • B
    Brett SimpsonSep 6, 2025
    What to do if Option switch settings do not match in Wintriss Shadow 8?
    • R
      Russell PetersonSep 7, 2025
      If the option switch settings do not match on your Wintriss Security Sensors, check to see that option switch positions 1 through 5 on the Main Receiver are set the same on both switch SWA and switch SWB.
  • C
    Christopher MillsSep 7, 2025
    How to fix corrupted EPROM configuration on Wintriss Shadow 8 Security Sensors?
    • E
      Erin WatersSep 7, 2025
      If you suspect a corrupted EPROM configuration in your Wintriss Security Sensors, reset option switches to their factory defaults.
  • R
    Ryan WoodardSep 23, 2025
    What to do if there is Error in segment 3 during operation of Wintriss Shadow 8?
    • C
      Crystal HartmanSep 23, 2025
      If there's an error in segment 3 during operation of your Wintriss Security Sensors, check connections to segment 3 and replace segment 3 with a known good segment.
  • J
    Jesse DennisAug 31, 2025
    Why Machine Run/Stop LED is green but press won’t start in Wintriss Security Sensors?
    • C
      christinecuevasAug 31, 2025
      If the Machine Run/Stop LED is green but the press won’t start on your Wintriss Security Sensors, check the stop relays on the Relay board on the optional Shadow 8 control box Main board.

Wintriss Shadow 8 Specifications

General IconGeneral
Number of Beams8
Housing MaterialAluminum
IP RatingIP65
Detection MethodInfrared
Operating Temperature0° to 50°C