en-18
6.6 Triggering a single lubrication sequence
You can trigger a single lubrication sequence at any time during operation with the lubricator.
MAX1
aLubricator in operation (PAU / On)
1. Hold the magnetic pin against the action field.
The LED flashes red.
2. Remove the magnetic pin when the display indicates run.
The lubricator performs a single lubrication sequence.
The LCD displays the approximate counter pressure and the pumping piston.
On completion of the lubrication sequence the lubricator returns automatically to operation.