Installation
29
Greenstar 8000 Life – 6720883866 (2019/04)
Water treatment products
Suitable water treatment products can be obtained from the following
manufacturers:
Table 12
4.7.1 Flushing the system
Flushing the system using existing appliance/circulating pump or new
appliance.
New appliances
A new appliance must only be used to assist the cleaning of a newly
installed system.
Fill the system with cold water and check for leaks.
Open vented systems only:
Turn off the water to the system header tank.
Open all drain cocks and drain the system.
Close drain cocks and add a suitable flushing agent compatible with
aluminium at the correct strength for the system conditions in
accordance with the manufacturer‘s instructions.
Mark the position of the lockshield valves and open them fully.
Fully open all TRVs.
Circulate the flushing agent before the appliance is fired up.
Run the appliance/system at normal operating temperature as
directed by the manufacturer of the flushing agent.
Drain and thoroughly flush the system to remove the flushing agent
and debris.
Appliances converted to sealed primary system only.
Do not drain the system through the PRV of new appliances.
It may be necessary to use a power flushing machine to aid the
cleansing procedure in some circumstances.
Close the drain cocks and manual air vents.
Existing appliance/circulating pump if continuing to use before
new appliance is installed.
Add a suitable inhibitor to the system in accordance with the
manufacturers instructions.
Open vented systems only:
Turn on the water to the system header tank and allow the system
to fill.
Appliances converted to sealed primary system only.
Fill the system to between 1 and 1.5 bar via a WRAS approved
filling loop.
Vent any air from the appliance and system.
New appliance.
Once the new appliance has been installed follow the guidance in
Filling the appliance and adding inhibitor section.
5 Installation
NOTICE:
Risk of damage to appliance or accessories.
All the previous pre-installation sections must be read and
requirements met before starting the appliance or flue installations.
CAUTION:
Risk of injury through incorrect lifting and carrying!
Only lift a manageable weight, or ask for help.
Bend the knees and keep the back straight with feet apart, when
lifting or putting down heavy objects.
DO NOT lift and twist at the same time.
Lift and carry object close to the body.
Appliance on site
Check contents of delivery are undamaged.
Remove the appliance from its packaging check the contents against
the scope of delivery.
Once the appliance is unpacked the installation can commence.
Important handling instructions
It is advised that two people are used to carry the carton from the van
to the point of delivery.
Once the carton has been delivered, the outer carton is removed first.
Care should be taken when releasing the straps. If a sharp implement
is used make sure the outer carton is not pierced and that the
implement is used in such a way so that it may not cause personal
injury.
All sharp objects must be covered or the blade retracted after use and
put away in a safe place. Care should be taken when lifting the
appliance from the base and the proper technique for safe lifting of
any heavy object should be strictly observed.
ADEY 01242 546717
www.adey.com
FERNOX 0870 601 5000
www.fernox.com
SENTINEL 0800 389 4670
www.sentinel-solutions.net