Technical Specifications/Logs
Greenstar 8000 Life – 6720883866 (2019/04)
68
Table 31 GR8300iW 50
12.2 Ionisation current
Table 32 Ionisation current
GR8300iW 50
Unit Natural gas Propane
1)
1) Propane/butane mixture for fixed containers with capacity up to 15 000 l
Gas flow maximum rate – 10 minutes from lighting
Natural Gas
2)
2) The Gas Rate provided assumes the accepted NG average calorific value of 34-9 MJ/m
3
net .
m
3
/h 5.1 –
Propane Gas (LPG) kg/h – 3.8
Central Heating (CH)
Maximum rated heat input (net) (Q
max
) kW 48.9 48.9
Maximum rated heat output 40/30 °C kW 50.0 50.0
Maximum rated heat output 50/30 °C (P
cond, max
) kW 49.9 49.9
Maximum rated heat output 80/60 °C (P
max
) kW 47.9 47.9
Minimum rated heat input (net) (Q
min
) kW 6.3 6.3
Minimum rated heat output 40/30 °C kW 6.8 6.8
Minimum rated heat output 50/30 °C (P
cond, min
) kW 6.7 6.7
Minimum rated heat output 80/60 °C (P
min
) kW 6.2 6.2
Maximum flow temperature °C 70 70
Maximum flow temperature possible °C 82 82
Maximum permissible operating pressure (PMS) bar 2.5 2.5
Flue
Flue gas temperature 80/60 °C, max/min load °C 73/56 73/56
Flue gas temperature 40/30 °C, max./min load °C 55/30 55/30
CO
2
level at max. rated heat output (after 10 minutes) % 9.5 10.8
CO
2
level at min. rated heat output (after 10 minutes) % 8.6 10.2
NO
x
class – 6 6
NO
x
rating (EN 15502-1) mg/kWh ≤ 40 ≤ 40
Condensate
Maximum condensate rate l/h 7.8 6.8
pH value, approx. – 4.5 – 5.0 4.5 – 5.0
Electrical
Electrical power supply voltage a.c. V 230 230
Frequency Hz 50 50
Maximum power consumption (running) W 75 75
Maximum power consumption (stand-by) W 1 1
General data
Appliance protection rating
3)
3) Protection rating may change depending on the control unit/s used on this appliance.
IP X4D X4D
Permissible ambient temperature short time/long time °C 0 – 50/40 0 – 50/40
Nominal capacity of the appliance l 4.2 4.2
Total packaged weight kg 56 56
Total appliance weight (excluding packaging) kg 48 48
Lift weight (without front and side panels) kg 42 42
When the burner is running at a minimum rated heat
Type Gas type OK Faulty
GR8300iW 30 R Natural gas ≥ 3 A < 3 A
LPG ≥ 3 A < 3 A
GR8300iW 35 R, GR8300iW 40 R, GR8300iW 45 R GR8300iW 50 R Natural gas ≥ 7 A < 7 A
LPG ≥ 10 A < 10 A