Technical Specifications/Logs
67
Greenstar 8000 Life – 6720883866 (2019/04)
Table 30 GR8300iW 40/45
GR8300iW 40 GR8300iW 45
Unit Natural gas Propane
1)
1) Propane/butane mixture for fixed containers with capacity up to 15 000 l
Natural gas Propane
1)
Gas flow maximum rate – 10 minutes from lighting
Natural Gas
2)
2) The Gas Rate provided assumes the accepted NG average calorific value of 34-9 MJ/m
3
net .
m
3
/h 4.3 – 4.6 –
Propane Gas (LPG) kg/h – 3.2 – 3.4
Central Heating (CH)
Maximum rated heat input (net) (Q
max
) kW 40.8 40.8 43.5 43.5
Maximum rated heat output 40/30 °C kW 41.4 41.4 44.9 44.9
Maximum rated heat output 50/30 °C (P
cond, max
) kW 41.2 41.2 44.7 44.7
Maximum rated heat output 80/60 °C (P
max
) kW 39.8 39.8 42.6 42.6
Minimum rated heat input (net) (Q
min
) kW 5.1 5.1 6.3 6.3
Minimum rated heat output 40/30 °C kW 5.5 5.5 6.8 6.8
Minimum rated heat output 50/30 °C (P
cond, min
) kW 5.5 5.5 6.7 6.7
Minimum rated heat output 80/60 °C (P
min
) kW 5.0 5.0 6.2 6.2
Maximum flow temperature °C 70 70 70 70
Maximum flow temperature possible °C 82 82 82 82
Maximum permissible operating pressure (PMS) bar 2.5 2.5 2.5 2.5
Flue
Flue gas temperature 80/60 °C, max/min load °C 77/56 77/56 69/56 69/56
Flue gas temperature 40/30 °C, max./min load °C 56/31 56/31 52/30 52/30
CO
2
level at max. rated heat output (after 10 minutes) % 9.5 10.8 9.5 10.8
CO
2
level at min. rated heat output (after 10 minutes) % 8.6 10.2 8.6 10.2
NO
x
class – 6 6 6 6
NO
x
rating (EN 15502-1) mg/kWh ≤ 40 ≤ 40 ≤ 40 ≤ 40
Condensate
Maximum condensate rate l/h 4.5 4.5 4.7 4.7
pH value, approx. – 4.5 – 5.0 4.5 – 5.0 4.5 – 5.0 4.5 – 5.0
Electrical
Electrical power supply voltage a.c. V 230 230 230 230
Frequency Hz 50 50 50 50
Maximum power consumption (running) W 63 63 68 68
Maximum power consumption (stand-by) W 1 1 1 1
General data
Appliance protection rating
3)
3) Protection rating may change depending on the control unit/s used on this appliance.
IP X4D X4D X4D X4D
Permissible ambient temperature short time/long time °C 0 – 50/40 0 – 50/40 0 – 50/40 0 – 50/40
Nominal capacity of the appliance l 4.2 4.2 4.2 4.2
Total packaged weight kg 54 54 56 56
Total appliance weight (excluding packaging) kg 46 46 48 48
Lift weight (without front and side panels) kg 40 40 42 42