Note: (1) the working voltage of brake is DC 24V.
(2) In the above diagram, BK signal output from SO1, please set P5-44 to n.0001. if it outputs
from SO2, please set P5-44 to n.0002.
3-4-2. Brake signal
Para
meter
Nam
e
Type
Default
setting
Meaning
Modify
P5-44
/BK
Outp
ut
n.0000
Not
distribute
output
terminal
Range 0000-0002, distribute to output
terminal through P5-44. When
P5-44=0001, it means output from
SO1.
3-4-3. The switch time between BK and SON
If the machine moves slightly due to gravity because of the brake has action delay time.
Please adjust the time as below parameter.
+24V
BK-RY
L
N
U
V
W
PE
SO1
COM
U
V
W
PE
M
PG
CN2
BK
1
2
3
Servo drive
+24V
BK-RY
Power supply
Servo motor with brake