The brake is used to protect the position. The brake must be effective at suitable time when
servo motor stop. Users can adjust the parameters according to the machine action.
The /BK signal from ON to OFF under either of the following conditions:
1. Motor speed drops below the value of P5-08 after servo OFF.
2. over the time of P5-09 after servo OFF.
4. Operation before using servo system
4-1. Operate panel
STA/ESC
DEC
INC
ENTER
power
/S-ON input or alarm
Occurs power off
Motor speed
(rpm)
/BK output
P5-08
Servo ON
Servo OFF
Brake ON
Brake OFF
P5-09
DB stop
Free stop