52
1
After the
instruction is
finished, the
deviation is below
P5-00 and COIN
signal is output.
U0-08
Pulse offset
P5-00
ON
/S-ON
Signal status
/COIN
Signal status
ONON
OFF
ΔU0-12
Pulse command
2
When the
instruction ends
and the motor
speed is under the
rotation detection
speed (P5-03) and
the absolute
deviation is less
than P5-00, the
COIN signal is
output.
U0-08
Pulse offset
P5-00
ON
/S-ON
Signal status
/COIN
Signal status
ONON
OFF
ΔU0-12
Pulse command
U0-00
Actual speed
P5-03
3
At the end of
instruction, the
absolute deviation
value under P5-00,
it outputs COIN
signal. If COIN
maintains P5-02
time, COIN-HOLD
signal is output.
U0-08
Pulse offset
P5-00
ON
/S-ON
Signal status
/COIN
Signal status
ONON
OFF
ΔU0-12
Pulse command
/COIN-HOLD
Signal status
ON
OFF
P5-02
P5-02
5.3.7 Positioning near signal/NEAR
Parameter
Signal name
Setting
Meaning
Range
P5-46
Positioning
near /NEAR
n.0000
(default)
Default unallocated output
terminal
The range of parameters
is 0001-0014.
can be assigned to other
output terminals through
P5-46.
n.0002
Output signal from SO2 terminal