31
4.3 Group U monitor parameters
U0-21 input signal status
STA/ESC
INC
DEC ENTER
12345678910
Lighting means that the corresponding
item has signal input.
Lighting means that the corresponding
item has no signal input.
U0-21 input signal 1 distribution
Segment
code
Description
Segment
code
Description
1
/S-ON servo enable
2
/P-CON proportion action instruction
3
/P-OT prohibition of forward
drive
4
/N-OT prohibition of reverse drive
5
/ALM-RST alarm reset
6
/P-CL forward side external torque limit
7
/N-CL reverse side external
torque limit
8
/SPD-D internal speed selection
9
/SPD-A internal speed selection
10
/SPD-B internal speed selection
Note: When reading through communication, the binary numbers read from right to left correspond to
the position of / S-ON, / P-CON, 0 means that the position signal is not input, 1 means that the
position signal has input. Example: 0x0001 means / S-ON has input, 0x0201 means / S-ON and /
SPD-B has input.