EasyManua.ls Logo

Xinje DS5E Series

Xinje DS5E Series
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
61
5.4.8 Set the segment number through communication
Parameter
Meaning
Default
setting
Unit
Range
Change
Effective
F2-09
Set the segment
number through
communication
0
-
035
Anytime
At once
This parameter is set to certain segment, it will execute this segment. No need step change signal. This
parameter can be changed through communication.
For example: execute segment 2. Set F2-09=0, then set F2-09=02.
5.4.9 Motion start signal/MRUN
Parame
ter
Meaning
Default
setting
Meaning
Change
P5-50
Motion
start
/MRUN
n.0000
Defaulted is not distribute to
output terminal. It is only
valid in internal position
mode, similar to positioning
complete signal in external
pulse mode. It will output
when the motor is running,
and will not output when the
motor stop.
Range 0000-0014, it can be
distributed to output terminal by
P5-50. When it is set to 0001,
means output signal from SO1.
5.5 Speed control (analog voltage command) (not support)

Table of Contents

Other manuals for Xinje DS5E Series

Related product manuals