5 input specifications and wiring methods
5-3-4AB Phase Counter's Frequency Multiplication Setting
To AB phase counter, user can modify the value in FLASH data registers FD8241, FD8242,
FD8243 to set the frequency multiplication value. When the value is 1, it is 1 time frequency;
when the value is 4, it is 4 times frequency.
1 For more information about high speed counter, please refer to XC series PLC user manual [Instruction
Part]
2 To some special model, only one axis can be set as one time frequency or 4 times frequency, the left two axis
are separately one time frequency and 4 times frequency.
XC5-24/32 PLCXCM-24/32 PLC
Increment Mode Pulse + direction mode AB phase mode
C600
C602
C604
C606
C608
C610
C612
C614
C616
C618
C620
C622
C624
C626
C628
C630
C632
C634
Max.
Freq.
80K
10K
80K
80K
4-time
Freq.
Count
Interrupt
X000 U
U
A
X001 Dir
B
X002
X003 U
X004
X005
X006
Register Function Setting Value
Content
1 1 time frequency
FD8241
Frequency Multiplication of
C630
4 4 time frequency
1 1 time frequency
FD8242
Frequency Multiplication of
C632
4 4 time frequency
1 1 time frequency
FD8243
Frequency Multiplication of
C634
4 4 time frequency